Burner plates;
Ignition / ionization;
Gas-air mixer.

 

 

Burner plates.                    

 

The burner plates allow precise positioning of the spark electrode in relation to the burner. Sight doors are equipped with heat-resistant knob for ease of inspection.

Special burner plate configurations are available to meet particular application requirements.

 

 

Ignition / ionization.         

 

We are using the double rod principle for burners over 1500mm (EU regulations EN-746-2)
One rod for ignition at the beginning of the burner.
One rod at to the end of the burner the flame signal is detected through ionization.
This double rod principle is preferable for understandable safety reasons.

ESG-400 Electronic Spark Generator
The ESG-400 is an electronic spark generator. It is special designed to operate in combination with the burner control unit IBA/421 series.

Technical specifications:
Input : 24 VAC 50/60 Hz (1 VA)
Output : 10 kV at 47 pF load
Max. Length ign. cable : 1.0 meter
Max diam. ign. cable : ø 7 mm
Temperature : 0 - 50°C (operating)

esg.jpg (21518 bytes)

 

 

Gas-air mixer.                           

 

The gas-air mixer is a proportional mixing device that utilizes the energy from a stream of air to entrain a combustible gas and delivers the mixture to the burners. Because of refinements in design this gas-air imixer will maintain accurate gas-air proportions at all flows when
supplied with zero pressure gas. This characteristics gives the combustion system a wider range of operation without requiring higher initial air pressure and reduces sensitivity with regards to burner flow characteristics.
Some advantages incorporated in the design of the Gas-air mixer are:

Use of flange connections eliminating unions in gas and air lines;
Easy access to entrainment insert for inspection, cleaning, or changing capacity without disconnecting gas on air lines;
Universal gas adjuster - good for any type of gas;
Installation flexibility (horizontal or vertical) right or left without special parts;
Available with manual or motorized Air Control Valve;

 

 